Rat sE-Selectin ELISA Kit

Rat sE-Selectin ELISA Kit

(Used in serum, plasma, cell culture supernatant and other biological fluids)

principle

This experiment uses the double antibody sandwich ABC-ELISA method. The anti-rat sE-Selectin monoclonal antibody was coated on the ELISA plate, the sE-Selectin in the standard and the sample was combined with the monoclonal antibody, and the biotinylated anti-rat sE-Selectin was added to form an immune complex connected to the plate On the top, the horseradish peroxidase-labeled Streptavidin is combined with biotin, the substrate working solution is added, the blue is added, and finally the stop solution sulfuric acid is added. The OD value is measured at 450nm. The concentration of sE-Selectin is proportional to the OD value, which can be passed Draw a standard curve to find the concentration of sE-Selectin in the specimen.

Kit composition (stored at 2-8 ° C)

Coated Wells

96 wells

Enzyme Conjugate

12ml

10 × Sample Buffer

12ml

20 × concentrated washing solution (Wash Buffer)

50ml

Standards (Standards): 400ng / bottle

2 bottles

Substrate working solution (TMB Solution)

12ml

The first antibody working solution (Biotinylated Antibody)

12ml

Stop Solution (Stop Solution)

12ml

Prepare reagents and collect blood samples

1. Collect specimens: serum, plasma (EDTA, heparin anticoagulation), cell culture supernatant, tissue homogenate, etc. as soon as possible, stored at 2-8 ℃ for 48 hours; longer time must be frozen (-20 ℃ or -70 ℃ ) Save to avoid repeated freezing and thawing. Serum and plasma should be diluted at least 1: 2 (take 50ul, add 50ul of sample dilution, and dilute twice).

2. Standard solution preparation: add 1ml of distilled water to mix well before use to make a 400ng / ml solution. Set 8 standard tubes, add 900ul of sample dilution in the first tube, and 500ul of sample dilution in the second to eighth tubes. Add 100 ul of 20 ng / ml standard solution to the first tube and mix it. Then aspirate 500 ul with the sampler and move to the second tube. Repeat the dilution in this manner repeatedly, draw 500ul from the seventh tube and discard it. The eighth tube is a blank control.

3. The 10 × specimen dilution is diluted 1:10 with distilled water (example: 1ml concentrated dilution + 9ml distilled water).

4. Washing solution: 1:20 dilution with redistilled water (example: 1ml concentrated washing solution is added with 19ml of redistilled water)

Testing procedures

1. Add sample: add 100ul of standard or sample to be tested to each well, mix the reaction plate thoroughly and place at 37 ℃ for 120 minutes.

2. Wash the plate: wash the reaction plate 4-6 times with the washing solution, and print it on the filter paper.

3. Add 100ul of the first antibody working solution to each well. The reaction plate was mixed thoroughly and then placed at 37 ° C for 60 minutes.

4. Wash board: same as above.

5. Add 100ul of enzyme-labeled antibody working solution to each well. Place the reaction plate at 37 ° C for 30 minutes.

6. Wash board: same as above.

7. Add 100ul of substrate working solution to each well, and place in a dark place at 37 ℃ for 15 minutes.

8. Add 100ul of stop solution to each well and mix well.

9. Measure absorbance at 450nm with a microplate reader within 30 minutes.

Result calculation and judgment

1. All OD values ​​should be calculated after subtracting the blank value.

2. With the standard products 40, 20, 10, 5, 2.5, 1.25, 0.625, 0 ng / ml as the abscissa and the OD value as the ordinate, draw a graph on the graph paper and draw a standard curve.

3. Find the corresponding sE-Selectin content on the graph according to the OD value of the sample, and then multiply it by the dilution factor.

Kit performance

1. Sensitivity: The smallest detection concentration of sE-Selectin is less than 3.2ng / ml.

2. Specificity: simultaneous detection of recombinant or natural rat sE-Selectin. Does not cross-react with other cytokines in rats.

3. Repeatability: The coefficient of variation within the board and the board is less than 9.7%.

Precautions

1. The above standard holes and samples to be tested are recommended to be re-holes, and the standard curve should be made at the same time for each measurement.

2. The washing process is critical. Insufficient washing will lead to an increase in accuracy error and OD value.

3. After opening the slats, the remaining slats should be sealed again to keep the slats dry.

4. This kit should be stored in a 4oC refrigerator.

5. This kit is for scientific research only, not for clinical diagnosis!

Inserted Pet Waste Bag

Product details
Leak Proof Each bag holds up to 10 lbs, sturdy enough for any business you need to handle. Pet Waste Bags These bags can handle any kind of duty. Make your walks a breeze with easy tear perforations, thicker leak-proof bags, and easy dispensing of pet waste bags when you need it. Easy Separation Perforations are made into each bag for easy separation. You don't need to worry about uneven tears. Every tear will be consistent! Clip On Any Leash The dog bone waste bag dispenser comes with a standard clip on attachment. Conveniently attach it to any leash. Dog Bone Waste Bag Dispenser Our pet waste bag bone dispenser is hard cased for durability and comes in a fun bone design. Dispense your waste bags easily and eliminate the hassles of fumbling with the bags. Easy To Use Each time you need to dispense a new roll, simply twist off the cap and insert a new one. The twist off cap ensures the roll stays secure and does not fall out.
500 strong quality pet waste bags – leak-proof
25 rolls, 20 bags per roll + free bone dispenser
Each bag is marked at perforation for easy separation
Color: Pastel Rainbow - Lavender Scented

Large bags, size: 12.5" X 8.5"

08 3

Inserted Pet Waste Bag,Pet Poop Plastic Pack,Disposable Pet Dog Poop Bags,Dog Pet Waste Poop Bags

Taizhou Jinchi Sanitary Product Co., Ltd , http://www.jstzjcpetwastebag.com

Posted on