Correct use of liquid chromatography column

First, the sample aspect

1. Remove particles and impurities

2. Understand the solubility of the sample in the mobile phase

If the solvent of the dissolved sample is not the mobile phase, the mobile phase must be tested for solubility to prevent precipitation in the mobile phase.

3. Understand whether the sample interacts with the matrix/filler of the column.

Second, the mobile phase

Remove particles

Purity requirements: ultrapure water, the content of organic impurities in the water is low during the gradient test; the pH value of the buffer is within the allowable range of the filler; the concentration of the buffer (salt); the organic solvent: chromatographically pure, the impurity content is as low as possible, And match the filler

2. Flow relative to the solubility of the sample

Organic solvent or water ratio

Third, the column cleaning

Have a good understanding of the sample you are doing, and clean it with the mobile phase that has the strongest elution ability.

The general method of the silica gel column is to first wash away the polar impurities with methanol, and then sequentially activate with dry dichloromethane and n-heptane 100~200ml.

The general method of bonding a phase column (alkyl group) is to sequentially rinse with 20 volumes of methanol-chloroform-methanol-water.

(Remember: There are specific methods for each column, so be sure to read the instructions first!)

Fourth, the storage of the column

Pre-storage treatment to remove impurities, buffer salts

Suitable storage solvent

Avoid drying up the column bed

Avoid mechanical vibration

Prevent bacterial growth

Pay attention to the stored temperature

Shanghai Jiapeng Technology Co., Ltd. specializes in: UV analyzer, three-use UV analyzer, dark box UV analyzer, black box UV analyzer, black box UV analyzer, portable UV analyzer, three-use UV analyzer, dark box , UV detectors, partial collectors, constant current pumps, peristaltic pumps, gel imaging systems, gel imaging analysis systems, chemiluminescence imaging analysis systems, photochemical reactors, vortex mixers, vortex mixers, glass chromatography columns, Gradient mixer, gradient mixer, nucleic acid protein detector, glass chromatography column, fluorescent whitening agent analyzer, fraction collector, rubber cutting instrument, blue gel cutting instrument, chromatography system and other products. Welcome to inquire.

Shanghai Jiapeng Technology Co., Ltd.

Adjustable Height Workbench

Our height adjustable workbench is made of high-carbon steel, and the surface treatment is powder-coated, which is durable. Below the simple appearance are the sturdy steel lifting column legs, which can bear a maximum weight of 120kg, which can meet daily needs. The adjustable workbench composed of four lifting columns has very good stability during the lifting process and will not shake or slide. The panel can be matched with a length between 79 inches and 94 inches, and a customized size service is provided for a variety of purposes, just for the product to better adapt to your use. 4 different height memory settings to adapt to almost any chair height or people of any height.

Adjustable Height Work Table

Height Adjustable Workbench,Adjustable Workbench,Electric Sit Stand Table,Adjustable Work Table

Suzhou Uplift Intelligent Technology Co., Ltd , https://www.up-lifting.com

Posted on